iCare® OX001 Oximeter, (SpO2) Blood Oxygen Saturation Monitor with Pulse Rate Measurements and Pulse Bar Graph, Digital Reading LED Display
-
ACCURATE READINGS - Our pulse oximeter has been clinically tested and consistently beat other pulse oximeter in terms of accuracy and reliability, it is found to be a fast and absolutely reliable gadget to use. It is ideal for the oxygen and pulse readings, and have a very small error margin.
-
SUITABLE FOR ADULTS AND KIDS - This device allows for almost all size of fingers from 2yrs old children to adults due to the finger chamber design.
-
SPORTS ENTHUSIASTS - Intended for sport and aviation use. This device is ideal for using during high endurance and outdoor sports such as mountain climbing, running, biking.
-
Oxygen saturation monitor shows real time Pulse Rate, Pulse Rate Bar and SpO2 level. Light Weight, Easy to carry & Accommodates wide range of finger sizes.
-
LOADED WITH ACCESSORIES - Package includes 2-AAA Batteries to power up the Pulse Oximeter, Wrist Cord, User Manual, plus 1 year warranty and friendly customer service.
Ck238 Digital BP Monitor
Not rechargeable; power with alkaline battery OR usb cord while using.
Huwag gamitin nang sabay ang battery at USB cord
Product Description:
● 1 Years Warranty
● 4 Ways for Power Supply
● Support USB Charger
● irregular Heartbeat Detector
● Two User Mode
● 180 Memory Storage
● Date / time function display
● Advanced Averaging
● BP Level Indicator
● Automatically turn off without any operation after 1 minute.
CMDN NO.: CDRRHR-CMDN-2022-1012103
• Measurement Accuracy: (Pressure) + 3mmHg (Pulse) +5% of reading
• Measuring Range: (Pressure) 0-290mmHg (Pulse) 40-180 pulse/min
• Resolution: 0.1kPa(1mmhg)
• Measurement: Oscillometric Method
• Automatic On/Off: Approximately 60 seconds
• Operating environment: +5°C to +40°C | 15%-85%RH
• Storage Environment: -20°C to +40°C | <93%RH
N61 MediMist Compressor Nebulizer
Basic Specs:
-
Power:
Input: AC100-240V,50Hz/60Hz
Output: DC12V,1000mA
2. Maximum nebulization rate:≥0.2mL/min
3. Mass median diameter(MMD): 3.9 μm± 25%Percent of MD < 5 μ m:> 65%※※
Test Condition: Temperature: 20, Relative humidity:53%,
Test distance: 10cm away from atomizing outlet,
Testsolution: 0.9% physiological saline.
(Test result changes withdifferent condition and solution.)
4. Maximum pressure of compression pump: ≥0.1MPa5.Free flow of compression pump: >3.5L/min
6. Noise: ≤60dB(A)
7. Net weight:about 220g(unit only)8.Size:Approx.14.5cm(l)x8cm(w)x5.6cm(h)
9.Taboo: None
10.Electrical safety requirements: Class Il equipment, Type BF applied part
11. Working system: intermittent operation -working for 20minutes with an interval of 40 minutes
12. Normal working conditions:
Ambient temperature:10℃~40℃
Relative humidity:30%~75%
Atmospheric pressure: 86kPa~106kPa
13. Transportation and storage environment conditions,
Ambient temperature:-40℃~+55℃
Relative humidity:10%~93%,no condensation
Atmospheric pressure:70kPa~106kPa
※Test conditions: The environmental temperature is 20℃ and the humidity is 53%. Atmosphere pressure 101.3 kPa. Test solution: 0.9% saline
(Change with test conditions and test solution)