CK238 Digital BP Monitor

 Not rechargeable; power with alkaline battery OR usb cord while using. 

Huwag gamitin nang sabay ang battery at USB cord  

 

Product Description:

● 1 Years Warranty

● 4 Ways for Power Supply

● Support USB Charger

● irregular Heartbeat Detector

● Two User Mode

● 180 Memory Storage

● Date / time function display

● Advanced Averaging

● BP Level Indicator

● Automatically turn off without any operation after 1 minute.

 

CMDN NO.: CDRRHR-CMDN-2022-1012103

 

• Measurement Accuracy: (Pressure) + 3mmHg (Pulse) +5% of reading

• Measuring Range: (Pressure) 0-290mmHg (Pulse) 40-180 pulse/min

• Resolution: 0.1kPa(1mmhg)

• Measurement: Oscillometric Method

• Automatic On/Off: Approximately 60 seconds

• Operating environment: +5°C to +40°C | 15%-85%RH

• Storage Environment: -20°C to +40°C | <93%RH

 

N61 MediMist Compressor Nebulizer

Basic Specs:

  1. Power:

Input: AC100-240V,50Hz/60Hz

Output: DC12V,1000mA

2. Maximum nebulization rate:≥0.2mL/min

3. Mass median diameter(MMD): 3.9 μm± 25%Percent of MD < 5 μ m:> 65%※※

Test Condition: Temperature: 20, Relative humidity:53%,

Test distance: 10cm away from atomizing outlet, 

Testsolution: 0.9% physiological saline.

(Test result changes withdifferent condition and solution.)

4. Maximum pressure of compression pump: ≥0.1MPa5.Free flow of compression pump: >3.5L/min

6. Noise: ≤60dB(A)

7. Net weight:about 220g(unit only)8.Size:Approx.14.5cm(l)x8cm(w)x5.6cm(h)

9.Taboo: None

10.Electrical safety requirements: Class Il equipment, Type BF applied part

11. Working system: intermittent operation -working for 20minutes with an interval of 40 minutes

12. Normal working conditions:

Ambient temperature:10℃~40℃

Relative humidity:30%~75%

Atmospheric pressure: 86kPa~106kPa

13. Transportation and storage environment conditions,

Ambient temperature:-40℃~+55℃

Relative humidity:10%~93%,no condensation

Atmospheric pressure:70kPa~106kPa

※Test conditions: The environmental temperature is 20℃ and the humidity is 53%. Atmosphere pressure 101.3 kPa. Test solution: 0.9% saline